MRTG Repository
Welcome to the MRTG/Denika/WebNM Templates Archive. Currently there are 196 templates available. Plixer International is constantly expanding this list with help from our customer base. Check out our extensive MIB Archive!
Visitors can search through our MIB database for OID strings to dynamically create templates to use with MRTG, Denika, and WebNM. Feedback for improvements is welcomed! Currently there are 314 devices in this database. MIBs are constantly being added to this database, so please check back often.
|
Port Errors Count |
This MIB-II Object will measure the number of errors per port from a network device such as a switch or router. |
![]() | |
|
Humidity for sensorProbe |
This template is used to measure the current Humidity from a humidity sensor. |
![]() | |
|
APC Line Voltage |
This template trend the line voltage for a scaled 230V input from systems running the PowerNET SNMP extensions. |
![]() | |
|
APC Input and Output Frequency |
This template will trend the current frequency reading from a APC device. |
![]() | |
|
APC Measure UPS Battery Temperature |
This templates will collect temperature data from a server running PowerNET SNMP Software. |
![]() | |
|
APC Measure UPS Battery Capacity |
This templates will trend the current battery capacity from a APC device. |
![]() | |
|
APC Measure UPS Adapter for Temperature |
This templates will collect the current temperature from a SmartUPS connected to system running PowerNET SNMP Extensions. |
![]() | |
|
APC Measure UPS Adapter for Humidity |
This templates will collect the current humidiy from a SmartUPS connected to system running PowerNET SNMP Extensions. |
![]() | |
|
APC Matrix Input and Output Voltage |
This templates will trend the input and output voltage readings |
![]() | |
|
Port Utilization by port instance |
This report template measures the amount of octets transferred and received to/from a specific port. When setting the BANDWIDTH parameter manually, the user must specify how many bytes per second can this port carry. Since most links are rated in bits per second, you need to divide their maximum bandwidth (in bits) by eight (8) in order to get bytes per second. |
![]() | |
|
APC UPS Output Current |
This template trend the output current from a APC UPS device. |
![]() | |
|
APC Current Capacity |
This template trend the current capacity from a APC UPS device. The value is expressed in percent of the rated capacity. |
![]() | |
|
Memory |
Memory Utilization for Cabletron Switches To find how much memory is installed on your switch use this OID .3.6.1.4.1.52.4.1.1.12.1.1.1.6.1.1) 8MB will be displayed in the MIB browser as 8 |
![]() | |
|
Total Retransmissions |
This attribute counts the total number of retransmissions to a station, over the wireless lan. It is updated only if syscollectperstationinfo is set to on. |
![]() | |
|
Storage Available |
This report template will measure the storage space available from devices that support the standard MIB-II host mib. |
![]() | |
|
CPU Utilization using Host MIB |
Use this template to create CPU Utilization from devices that support the Standard MIB-II Host MIB. Windows NT systems will not report this value. Users must use the Perfmon CPU Utilization Report. |
![]() | |
|
Number of processes using Host MIB |
This template will trend the number of current processes on a system that support the HOST MIB. |
![]() | |
|
Number of current users using the Host MIB |
This template will trend the current number of user connections on a system that supports the Host MIB. |
![]() | |
|
QOS Bytes per Class |
This report template measures the amount of octets matching a specified Class Map |
![]() | |
|
APC High and Low Input Line Voltage |
This template trend the high and low line input voltage for a scaled 230V input. |
![]() | |
|
APC Current Out Load Capacity & Amperes drawn |
This template trend The current UPS load expressed in percent of rated capacity (green) and the current in amperes drawn by the load on the UPS (blue). |
![]() | |
|
APC Input and Output Voltage |
This templates will trend the input and output voltage readings |
![]() | |
|
APC Measure UPS Environ Temperature for Porbe1 |
This templates will collect the current temperature from the ambient temperature in Celsius for Probe 1. |
![]() | |
|
APC Measure UPS Relative Humidity for Probe 1 |
This templates collect the current relative humidity as a percentage for Probe 1. |
![]() | |
|
APC UPS Output Current Load |
This template trend the output current from a APC UPS device. |
![]() | |
Vendors -> -> Standard MIB-II Templates | |
|
Bad SNMP Gets |
The total number of community-based SNMP messages (for example, SNMPv1) delivered to the SNMP entity which used an SNMP community name not known to said entity. Also, implementations which authenticate community-based SNMP messages using check(s) in addition to matching the community name (for example, by also checking whether the message originated from a transport address allowed to use a specified community name) MAY include in this value the number of messages which failed the additional check(s). It is strongly RECOMMENDED that the documentation for any security model which is used to authenticate community-based SNMP messages specify the precise conditions that contribute to this value. |
![]() | |
|
Cached Non-Moveable Memory in Use |
Cache Non-Moveable Memory in use as a percentage of total memory from a device that supports the MIB-II Host MIB. Researched and configured by Garth K. Williams. |
![]() | |
|
Code and Data Memory in Use |
Code and Data Memory in use as a percentage of total memory from a system that supports MIB-II host. Researched and configured by Garth K. Williams. |
![]() | |
|
CPU Utilization |
CPU Utilization on a processor from this Novell Server Researched and configured by Garth K. Williams. |
![]() | |
|
CRC errors |
Measures CRC errors on an interface |
![]() | |
|
Frame Relay DLCI Utilization |
This report measure the amount of bandwidth going in and out of a frame relay connection. |
![]() | |
|
Frame Relay FECNS/BECNS Count |
This report template measures FECNs (Forward Explicit Congestion Notifications) and BECNs (Backword Explicit Congestion Notifications) on a frame relat circuit based on a 5 minute polling interval. |
![]() | |
|
Interrupts per Second |
Interrupts per Second using MS perfmon Counters |
![]() | |
|
NLMs loaded |
Number of Processes (NLMs) loaded on a Novell Server. Researched and configured by Garth K. Williams. |
![]() | |
|
Number of Users |
Number of Users attached to a system that supports the Host MIB. Researched and configured by Garth K. Williams. |
![]() | |
|
Port Utilization by description |
This port utilization template should be used with devices that have dynamic SNMP instances for the port. This report template measures the amount of octets transferred and received to/from a specific port. When setting the BANDWIDTH parameter manually, the user must specify how many bytes per second can this port carry. Since most links are rated in bits per second, you need to divide their maximum bandwidth (in bits) by eight (8) in order to get bytes per second. |
![]() | |